STANDARD FOR SAFETY
Test Method for Evaluating Thermal
Runaway Fire Propagation in Battery
Energy Storage Systems
SCC
CCN
ANSI/UL 9540A-2025
SCC FOREWORD
National Standard of Canada
A National Standard of Canada is a standard developed by a Standards Council of Canada (SCC)accredited
Standards Development Organization,in compliance with requirements and guidance set out by SCC.More
information on National Standards of Canada can be found at www.SCc.ca.
SCC is a Crown corporation within the portfolio of Innovation,Science and Economic Development(ISED)Canada.
With the goal of enhancing Canada's economic competitiveness and social well-being,SCC leads and facilitates the
development and use of national and international standards.SCC also coordinates Canadian participation in
standards development,and identifies strategies to advance Canadian standardization efforts.
Accreditation services are provided by SCC to various customers,including product certifiers,testing laboratories,
and standards development organizations.A list of SCC programs and accredited bodies is publicly available at
WWw.SCC.ca.
MARCH 12,2025-ANSI/CAN/UL9540A tr1
UL Standard for Safety for Test Method for Evaluating Thermal Runaway Fire Propagation in Battery
Energy Storage Systems,ANSI/CAN/UL9540A
Fifth Edition,Dated March 12,2025
Summary of Topics
This Fifth Edition of ANSI/CAN/UL9450A,Standard for Test Method for Evaluating Thermal
Runaway Fire Propagation in Battery Energy Storage Systems dated March 12,2025,includes the
following changes in requirements:
-Revised FTIR measurements to be optional and added hydrogen measurements at Unit
Level Test:8.2.14,8.2.15,9.2.23,9.2.24, and 10.3.13.
-Clarified sample rest times after conditioning and charging:7.2.2,8.1.2, and 9.1.9.
-Corrected standard reference in 9.1.12:3.2.
-Replaced reference to UL 1685 with UL 2556:3.2 and 10.2.2.
-Revised Residential Unit Level Testing to remove the usage of the NFPA 286 test room and
replaced with test wall:9.1.2,Figure 9.3,9.2.6,9.4.2,9.4.3,9.5.1,9.5.2, and 10.3.3.
-Added option for continuous thermal ramp until thermal runaway:7.3.1.5.
-Added NFPA 855 for applicable codes: 1.2 and 3.2
-Clarified charging method for cells: 7.2.1 and 7.2.4
-Revised location of thermocouples during cell testing and thermal ramp option:7.3.1.2,
7.3.1.7-7.3.1.10.
-Clarified report if using a battery system as the BESS unit for testing: 7.7.1.
-Clarified establishing cell to cell propagation in the test method in 8.2:8.2.3- 8.2.7.
-Revised Module Level Performance Criteria:8.5.1.
-Revised requirements to allow the use of Gardon heat flux gauge,revised sampling rate
for heat flux and wall temperature,and added floor mounted residential system exceptions:
6.3,6.4,9.2.15,9.2.17 -9.2.20,10.3.5,10.3.6,10.3.8 -10.3.10.
-Revised egress path heat flux measurements for non-residential outdoor wall mount
systems: 9.5.1 and 9.5.5.
-Removed noncombustible construction exception and clarified outdoor flame exception:
4.16,9.1.1,9.1.6,9.2.19,9.3.2,9.6.1 - 9.6.5,9.7.1, and Table 9.1.
-Added test method for lead acid and nickel cadmium batteries:3.2, 7.3.1.4, 7.3.3.1 - 7.3.3.8,
7.6.1,7.6.2,Table 7.1,7.7.3,and 7.10.1- 7.10.4.
-Revised flow battery requirements: 5.4.3,7.1.1,7.1.2, Section 7.3.2,7.7.2,7.9.1,9.9.1-
9.9.4,9.10.1, and 9.11.1.
摘要:

ANSI/CAN/UL9540A:2025JOINTCANADA-UNITEDSTATESNATIONALSTANDARDSTANDARDFORSAFETYTestMethodforEvaluatingThermalRunawayFirePropagationinBatteryEnergyStorageSystemsSCCCCNANSI/UL9540A-2025SCCFOREWORDNationalStandardofCanadaANationalStandardofCanadaisastandarddevelopedbyaStandardsCouncilofCanada(SCC)accred...